CUET-PG — Environmental Sciences · India · National Testing Agency
Original practice questions written to the published syllabus · not past papersHow environmental samples are taken and analysed and how good the numbers are: sampling plans, gravimetric and volumetric methods, spectroscopy, chromatography, quality assurance and monitoring networks.
In the exams: UGC NET Environmental Sciences Unit 2; ICAR AIEEA-PG Physical Science Unit II (instrumental analysis); ICAR AICE Aquatic Environmental Management Unit 3
How our questions for CUET-PG spread across the units of Environmental Monitoring & Instrumental Analysis. Difficulty: 23 easy, 1 medium, 0 hard.
| Sampling and preservation of water, soil, air and biota | 3 | |
| Bioindicators and biomonitoring | 3 | |
| Monitoring objectives and network design | 2 | |
| Gravimetric and volumetric analysis | 2 | |
| UV-visible spectrophotometry and colorimetry | 2 | |
| Atomic absorption and ICP techniques | 2 | |
| Gas and liquid chromatography; mass spectrometry | 2 | |
| Electrochemical methods and sensors | 2 | |
| Stable and radioactive isotopes in environmental analysis | 2 | |
| Detection limits, accuracy, precision and calibration | 2 | |
| Quality assurance, quality control and laboratory accreditation | 1 | |
| Continuous and low-cost sensor monitoring | 1 |
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
How should water samples for dissolved metal analysis usually be preserved?
D. Filtration and nitric acid to pH below 2
Nitric acid keeps metals in solution and prevents adsorption; thiosulphate is for chlorinated microbiological samples.
Further reading: See the manual sources: Standard Methods; Harris; Skoog et al.; CPCB monitoring guidelines; ISO/IEC 17025
Why are volatile organic compound water samples collected in vials with no headspace?
D. To stop VOCs escaping into the vial air
Headspace would let volatile analytes partition out of the water.
Further reading: See the manual sources: Standard Methods; Harris; Skoog et al.; CPCB monitoring guidelines; ISO/IEC 17025
At what temperature is the residue dried for total dissolved solids?
A. 180 °C
TDS residue is dried at 180 °C; TSS at 103–105 °C; volatile solids are ignited at 550 °C.
Further reading: See the manual sources: Standard Methods; Harris; Skoog et al.; CPCB monitoring guidelines; ISO/IEC 17025
Which GC detector is extremely sensitive to halogenated compounds such as organochlorine pesticides?
A. Electron capture detector
ECD responds strongly to electronegative halogens; FID is general for organics; TCD is universal but insensitive.
Further reading: See the manual sources: Standard Methods; Harris; Skoog et al.; CPCB monitoring guidelines; ISO/IEC 17025
Electrical conductivity of water increases mainly with
D. the concentration of dissolved ions
Ions carry current; conductivity indicates dissolved salts.
Further reading: See the manual sources: Standard Methods; Harris; Skoog et al.; CPCB monitoring guidelines; ISO/IEC 17025
Which international standard is used for hydrogen and oxygen isotope ratios in water?
A. Vienna Standard Mean Ocean Water (VSMOW)
VSMOW for H and O; VPDB for carbon; air N2 for nitrogen; CDT for sulphur.
Further reading: See the manual sources: Standard Methods; Harris; Skoog et al.; CPCB monitoring guidelines; ISO/IEC 17025
Replicate measurements have a mean of 10 mg/L and a standard deviation of 0.5 mg/L. What is the relative standard deviation?
A. 5 per cent
RSD = 0.5/10 × 100 = 5%.
Further reading: See the manual sources: Standard Methods; Harris; Skoog et al.; CPCB monitoring guidelines; ISO/IEC 17025
Which QC sample detects contamination introduced during field handling and transport?
B. Field blank
Field blanks are analyte-free water taken through field procedures; spikes test recovery; CRMs test accuracy.
Further reading: See the manual sources: Standard Methods; Harris; Skoog et al.; CPCB monitoring guidelines; ISO/IEC 17025
Beta attenuation monitors are used to measure
B. particulate matter mass concentration
BAMs measure the attenuation of beta radiation by particles collected on filter tape.
Further reading: See the manual sources: Standard Methods; Harris; Skoog et al.; CPCB monitoring guidelines; ISO/IEC 17025
Which organisms are classic bioindicators of sulphur dioxide air pollution?
B. Lichens
Many lichens are sensitive to SO2; lichen diversity maps air quality.
Further reading: See the manual sources: Standard Methods; Harris; Skoog et al.; CPCB monitoring guidelines; ISO/IEC 17025