Why hydroponic fertiliser needs two tanks

Short · · 56 s

Concentrated calcium reacts with sulphates and phosphates and falls out of solution, so hydroponic stocks are kept in two tanks: A (calcium nitrate, potassium nitrate, iron) and B (phosphates, sulphates, magnesium, micronutrients), diluted about 1:100. Then check EC (about 1.5–3.0) and pH (about 5.5–6.5).

Hydroponics and soilless culture →

Subscribe on YouTube

The chemistry behind the split

Calcium sulphate (gypsum) dissolves only to about 2 grams per litre, and calcium phosphates are far less soluble still. In a dilute nutrient solution the calcium, sulphate and phosphate ions stay apart and available, but in a concentrate a hundred times stronger they meet, bind and settle out as a white sludge. That sludge blocks drippers and filters, and the calcium and phosphorus locked in it never reach the roots, so plants can show calcium-related disorders such as tipburn in lettuce or blossom-end rot in tomato even though the recipe was correct on paper.

Iron is kept on the calcium side for a related reason: at high strength, iron and phosphate can also combine into an insoluble iron phosphate, and the chelate holding the iron is more stable away from the phosphate-rich concentrate.

What usually goes in each tank

A common layout puts calcium nitrate, part of the potassium nitrate and the iron chelate in the A stock. The B stock carries monopotassium phosphate, potassium sulphate, magnesium sulphate, the rest of the potassium nitrate, and the trace elements: manganese, zinc, copper, boron and molybdenum. Nitric or phosphoric acid used to correct alkaline water is normally added to B or to a separate acid tank, never mixed neat with A.

Each stock is diluted through its own injector or dosing head, typically at 1:100 or 1:200, into the same water stream. Many growers in Europe, North America and Australia also run a third tank for acid or base.

Mixing the stocks safely

Fill each tank about two-thirds with clean water first, dissolve salts one at a time while stirring, and then top up to the mark. Warm water helps calcium nitrate dissolve, but it cools sharply as it goes in. Label tanks clearly, use separate jugs and scoops for A and B, and never pour one concentrate into the other or into the same small bucket. When filling a reservoir by hand, add A to the water, stir well, then add B.

Checking the final solution

Measure electrical conductivity (EC) and pH in the solution the plants actually receive, not in the stocks. Leafy greens are often run around 1.2 to 2.0 mS/cm, fruiting crops such as tomato and cucumber about 2.5 to 3.5, adjusted for stage and climate. Keep pH roughly between 5.5 and 6.5; above about 6.5, iron and manganese become less available and calcium phosphate can form even in the dilute solution.

Calibrate EC and pH meters weekly with fresh buffer and standard solutions, because drifting meters cause more problems than wrong recipes. In closed systems, a laboratory analysis every few weeks shows which ions are building up or running short, since EC only reports the total.

Signs that something has gone wrong

A cloudy or milky reservoir, white crust in pipes or drippers, or a sudden fall in EC soon after mixing points to precipitation. Check whether someone combined the concentrates, whether the water is very hard or high in bicarbonate, and whether pH has crept up. Start-up mistakes are common: get a water analysis before choosing a recipe, as hard well water in places such as the Mediterranean, the Middle East or parts of Mexico may already supply much of the calcium and magnesium.

Sources: Resh HM, Hydroponic Food Production, 7th edition, CRC Press, 2013 · Sonneveld C, Voogt W, Plant Nutrition of Greenhouse Crops, Springer, 2009 · Hoagland DR, Arnon DI, The water-culture method for growing plants without soil, California Agricultural Experiment Station Circular 347, 1938/1950

Transcript

Why do hydroponic growers keep their fertiliser in two separate tanks?

Because when they are concentrated,

calcium reacts with sulphates and phosphates, and falls out of solution as a solid your plants cannot use.

So tank A holds calcium nitrate, potassium nitrate and iron.

Tank B holds the phosphates, the sulphates, magnesium and the micronutrients.

The number to remember is one hundred. An injector dilutes both tanks into the water, often at one part in a hundred.

Never mix the two concentrates directly.

Then check the final solution:

an EC of about one point five to three, and a pH of about five point five to six point five.

The full hydroponics guide is in our long video and at laisha.ai.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Go further with Laisha Smarter

US$10 a month · one price worldwide · cancel any time

  • Ask Laisha about what you watched — up to 1,000 questions a month
  • Your own crop calendar and pest alerts
  • Every calculator and tool
10 days free for every new account, no card.